Critical Care • Pulmonary Physiology • Interactive Curriculum

Respiratory Mechanics

From the equation of motion to mechanical power: five case-based teaching sessions for residents and pulmonary–critical care fellows, with original waveform visualizations, bedside calculators, formative MCQs, and a scored final examination.

5 lessons20 formative questions15-question final examRuns offline • No dependencies

Study the lessons in any order. Your answers are saved in this browser when storage is available.

Session 1 · Foundations

The respiratory system is an elastic reservoir behind a resistive tube

Build a one-compartment model, derive the equation of motion, and calculate how compliance, resistance, and flow set airway pressure.

~15–20 minutes

1. What does the ventilator actually have to overcome?

The source review starts with a simple model: a tube (conducting airways and endotracheal tube), a balloon (lung and chest wall), and a driving force supplied by the ventilator and, in assisted breaths, respiratory muscles.

Elastic load

Pressure required to inflate the lung and chest wall; depends on volume and the inverse of compliance.

Resistive load

Pressure needed to move gas through airways; depends on flow and resistance. It disappears when flow stops.

Paw = PEEPtotal + V/Crs + Raw × V̇

Simplified equation of motion for a passive, linear respiratory system. V is volume above the starting end-expiratory volume (L); C in L/cmH₂O; R in cmH₂O/(L/s); flow in L/s.

At zero inspiratory flow, the resistive term vanishes, explaining why an inspiratory hold separates peak from plateau pressure.

The waveform is not decoration: it is the equation of motion displayed against time.

2. Calculate before interpreting

  • Compliance Crs = VT / (Pplat − PEEPtotal).
  • Elastance Ers = 1/Crs.
  • Resistance Raw = (Ppeak − Pplat) / inspiratory flow, with constant-flow VC and a passive patient.
  • Driving pressure ΔP = Pplat − PEEPtotal = VT/Crs.
Use total PEEP when intrinsic PEEP exists. For example, Pplat − set PEEP overestimates driving pressure and underestimates compliance if total PEEP is higher.
Session 2 · Bedside waveforms

Interpret peak, plateau, stress index and pressure–volume loops

Identify what a pressure tracing can—and cannot—tell you about resistance, elastic load, recruitment, and overdistension.

~15–20 minutes

1. Peak pressure versus plateau pressure

Ppeak combines elastic and resistive pressures, but an end-inspiratory pause makes flow approach zero and allows Paw to equilibrate toward Pplat. If Ppeak rises but Pplat stays stable, think increased resistance; if Pplat rises, assess compliance and total PEEP.

High Ppeak, unchanged Pplat

Think secretions, bronchospasm, small/kinked ETT or increased inspiratory flow.

High Ppeak and Pplat

Think worsening elastance, higher end-expiratory pressure or an evolving mechanical load.

Do not interpret a plateau measurement during forceful patient effort as if the patient were passive.

2. Stress index: curvature under constant flow

In a passive volume-controlled breath with constant inspiratory flow, the shape of the pressure–time tracing can reveal how compliance changes as lung volume increases. This interpretation is not valid for variable-flow breaths or strong effort.

Index < 1 · downward concavity

Compliance improves as volume increases: tidal recruitment may be occurring.

Index = 1 · linear

Near-constant compliance during inflation.

Index > 1 · upward concavity

Compliance worsens with inflation: possible overdistension.

P–V hysteresis

Recruitment and derecruitment may make the inflation and deflation limbs diverge.

Session 3 · Expiration

Time constants, dynamic hyperinflation and intrinsic PEEP

See why an obstructed lung may still be emptying when the next breath begins—and why the flow baseline matters.

~15–20 minutes

1. How long does a lung unit take to empty?

τ = R × C  ;  V(t) = V₀ × e−t/τ

One time constant (τ) removes about 63% of the excess volume during ideal passive expiration; three remove ~95%, and five ~99.3%. The review emphasizes that lung units with higher resistance or compliance have longer τ and require more time to empty.

ContextExpiratory time constant
Normal lung~0.5–0.7 s
ARDSUsually < 0.5 s
COPDUsually > 0.7 s

Approximate patterns from Table 1 in Gertler (2021); individual patients can differ substantially.

2. Why auto-PEEP develops

Inspiratory flow is conventionally positive; expiratory flow negative. Expiration should cross back to zero flow before the next inspiration. When expiration is prematurely interrupted, negative expiratory flow remains and the lung retains volume, creating dynamic hyperinflation and intrinsic PEEP.

A baseline that is not explicitly drawn makes auto-PEEP much harder to recognize. The source review’s Figure 3 uses the negative-flow limb and incomplete return to zero as its central visual clue.
  1. Check the flow–time waveform for unfinished expiration.
  2. In a passive patient, perform an end-expiratory hold: auto-PEEP = total PEEP − set PEEP.
  3. Address minute ventilation, expiratory time and airway resistance; monitor hemodynamics and effort.
Session 4 · Partitioning mechanics

Transpulmonary pressure, chest-wall elastance, PEEP and recruitment

Learn why the same plateau pressure can reflect very different forces across the lung in an obese patient versus a patient with normal chest-wall mechanics.

~15–20 minutes

1. Respiratory system ≠ lung alone

1/Crs = 1/Clung + 1/Cchest wall

Both lung and chest wall must expand. In morbid obesity, abdominal distension, pneumoperitoneum or thoracic restriction, the measured plateau pressure may rise because more pressure is spent expanding the chest wall—not necessarily because the lung is overdistended.

Transpulmonary pressure

PL = Palv − Ppleural ≈ Paw,static − Pes

Esophageal pressure is a practical (imperfect) pleural-pressure surrogate. During static holds, end-expiratory and end-inspiratory transpulmonary pressures can inform bedside physiology.

Absolute esophageal pressure depends on position, mediastinal effects and balloon technique. Positive end-expiratory PL is a physiologic target described in the review, not an automatic instruction to raise PEEP.

2. PEEP: recruitment versus overdistension

PEEP can decrease cyclic collapse yet increase static strain. The review proposes evaluating compliance, driving pressure, oxygenation, ventilation and hemodynamics together; a single oxygen saturation or lung-volume change does not prove recruitment.

Possible beneficial response

Improved Crs, reduced ΔP at fixed VT, better oxygenation without circulatory compromise.

Concerning response

Increased ΔP, falling compliance or worsened hemodynamics after higher PEEP.

Where bedside imaging adds value

Electrical impedance tomography (EIT) depicts regional ventilation and can help distinguish dependent collapse from nondependent overdistension, complementing global measures. Lung ultrasound is another adjunct described in the review.

Session 5 · Integration

Mechanical power, VILI and assisted ventilation

Put flow, pressure, volume, rate, chest-wall mechanics and patient effort into a single physiologic interpretation.

~15–20 minutes

1. Energy per breath × breaths per minute

The article frames mechanical power as the rate of energy transfer during ventilation. Important contributions include PEEP-related pressure, tidal elastic distension, and resistive flow, multiplied across the respiratory rate.

Mechanical power = respiratory rate × inflation energy per breath

Higher VT, driving pressure, rate, PEEP and flow may increase the total mechanical energy delivered. Crucially, equal power does not mean equal injury risk: lung size, recruitability, regional mechanics and underlying disease all matter.

Treat mechanical power as a synthesis of interacting variables—not as a replacement for individual safety checks or clinical judgment.

2. VILI and patient-generated effort

  • Volutrauma / barotrauma: excessive distension, stress and strain.
  • Atelectrauma: repeated collapse and reopening of unstable units.
  • Biotrauma: inflammatory consequences of mechanical injury.
  • Oxytrauma: injury associated with excessive oxygen exposure.
  • P-SILI: vigorous spontaneous inspiratory effort may increase transpulmonary stress even when airway pressure appears acceptable.

In pressure-targeted modes, strong patient effort can increase volume and flow despite a fixed Paw. In volume control, it can deform Paw downward although delivered flow and volume are preset. These distinctions follow the source’s discussion of spontaneous muscle pressure and patient–ventilator interaction.

A reassuring ventilator pressure waveform does not exclude excessive regional stress during strong patient effort.

3. A five-question bedside synthesis

  1. What is the patient's lung-protective tidal volume based on predicted body weight?
  2. Is the patient passive enough for valid Pplat, total PEEP and Crs measurements?
  3. Are the resistive, elastic and expiratory mechanics changing?
  4. Could chest-wall stiffness explain part of the measured pressure?
  5. Are effort, regional recruitment and hemodynamics consistent with the chosen settings?
Final exam · 15 questions

Clinical respiratory mechanics: integrated reasoning exam

Each question has one best answer. Answer all 15, submit once, then review your score with explanations. Pass benchmark: 80% (12/15).

~20–25 minutes

Exam instructions

Questions include calculations, waveform interpretation, obstructive physiology, chest-wall mechanics, PEEP titration, and mechanical power. Use the values given. No timer, sign-in, or internet connection is required.

Answered0 / 15 questions

You may change answers before submitting.